Description of regulation

nalepka

Burning up mode

The burning process can be start by pressing button "K". On the regulation panel shines on control lights (6), (11), (14), (15). Control lights (11) and (14) are shining, as far as shines on control light (17) automatic operation. Control light (17) shines on, if case the temperature of output water will have in 3°C lower temperature as set up temperature. If we set up temperature 70°C, control light shines on at 67°C.
After control light (17) shines on can occur:
  • switchover of fan to the low speed cycle, which shows control light (13).
    The fan stays on the low speed cycle till the temperature of set up water is the same as set up temperature. In case that fan at low speed cycle can't heat up the boiler to the requested temperature and temperature is decreasing, fan automatically switch to high speed cycle. In case of fan at low speed cycle heat up the boiler to requested temperature, directly after fan raise the temperature is automatically turned off.
    On the panel are shining control lights (6), (8), (15), (17). The fan turn on itself automatically, when the temperature decrease in 5°C from set up temperature. This mode repeat automatically if is necessary. (so called AUTOMATIC OPERATION)
  • the boiler is out of order by switch clock in to the temper mode, see next chapter "Switch clock".

Boiler shutdown

The boiler is shutdown by pressing the button "K", or when the output water temperature decrease under 30°C. Into the SHUTDOWN mode or AUTOMATIC OPERATION mode is possible by pressing the button "K" once again.

Setting of the boiler parameters

Setting of the boiler parameters is possible to do it by these buttons:
“F“ - function selection
“+“ - increase chosen value
“-“ - decrease chosen value

Actual temperature of output water

At basic state is indicated Real temperature of output water and display shows temperature value in °C . Each time when you press button "K" you will jump in to the basic state.